cqms-header-logocqms-header-logocqms-header-logocqms-header-logo
  • Welcome
  • Consultancy Services
    • Competent Person Service
    • Health and Safety Documentation
    • Audits & Inspections
    • CDM Consultancy
  • Safety Scheme Services
    • Safety Scheme Assessment & Certification
    • Supply Chain Management
    • Safety Scheme Portal
    • Safety Scheme Fees
    • Apply Now
  • Training
    • Health and Safety Training Courses
    • Online training courses
    • IOSH Managing Safely
  • Resources
    • Insights
      • Corporate Manslaughter cases
      • Recent Prosecutions
      • HSE Alerts
      • News Articles
      • Guidance
    • FAQs
    • Shop
  • About us
    • Who is CQMS
    • Accreditation, Certification & Memberships
    • Testimonials
    • Privacy Notice
  • Get in Touch
0

£0.00

✕

Company fined following fatal gas explosion

8th June 2021

An asbestos removal contractor has been fined after a worker was fatally injured and another worker seriously injured in a gas explosion.

Hamilton Sheriff’s Court heard how on 5 October 2017, workers were removing a boiler and pipework, and overspraying walls to remove asbestos residue, at the former Pastoral Centre in Bonkle Road, Newmains in Wishaw.

The work was being carried out prior to demolition. The plan was to cut the boiler and pipework into sections to make it easier to remove. However, the gas supply had not been isolated and the workers cut through a live gas outlet pipe, the gas ignited causing an explosion.

Two workers received extensive burns to their body and underwent surgery. One of the employees died in hospital several days after the incident.

An investigation by the Health and Safety Executive (HSE) identified that the risk assessment and plan of work for the job had identified services were present in the boiler room, but the company failed to ensure the gas pipe was isolated and purged of gas before work commenced.

Enviraz (Scotland) Limited of Kelvin Avenue, Hillington Business Park, Glasgow pleaded guilty to breaching Section 2(1) of the Health and Safety at Work etc Act 1974. The company was fined £150,000.

Speaking after the hearing, HSE inspector Helen Diamond said: “This incident could so easily have been avoided if the company had ensured that the gas pipe in the boiler room had been isolated and purged prior to removal. Within the asbestos licensing permissioning regime, HSE expects licensed contractors to have adequate management arrangements in place to control non-asbestos risks.

“Given the potential consequences of using a power tool on live or unpurged pipework, the management system to establish the status of the pipework needs to be robust and there should be written confirmation of isolation.

“Tragically, one man has lost his life as a result of this incident and a second worker has sustained life-changing injuries.”

Source HSE Website 27/04/2021

For more HSE news including prosecutions visit the HSE website

Share

Related posts

29th March 2024

Director jailed for failing to protect workers from asbestos exposure


Read more
29th March 2024

Tobacco firm fined £32,000 following machinery failures


Read more
28th March 2024

Company fined after worker crushed to death


Read more

Get in touch

CQMS Limited
The Clock, 12-13 Westgate, Grantham, Lincolnshire, NG31 6LT
Tel: 01476 566 665
Email: enquiries@cqms-ltd.com

Connect with us on social media

CQMS Safety-Scheme is a UKAS-accredited Type C Inspection Body under ISO 17020:2012 for the provision of health and safety assessment services’
CQMS Safety-Scheme - UKAS-accredited Type C Inspection Body under ISO 17020:2012

Search our site

✕

External Links

H&S Executive Website
Incident Contact Centre
The British Safety Council
RoSPA

© 2017 - 2025 CQMS Limited | Registered office address: Nationworld House, Noose Lane, Willenhall, England, WV13 3AP Company number: 02950076 | All rights reserved | Site built and hosted by GIGER MEDIA | Content managed by CQMS
    0

    £0.00

      ✕

      Login

      Lost your password?